In that climate the thermal mass of an inch or two of concrete on top of the roof deck plus an inch of polyiso on top of that does quite a bit for thermal performance if the structure can take the load.
Rigid insulation on top of roof deck.
Benefits of rigid foam on top of sheathing.
An excellent fire barrier densdeck roof boards feature a noncombustible core and inorganic surface that offer greater fire protection than other conventional commercial roofing products when applied over combustible roof decks and steel decks.
6 of rigid iso with or without pre applied nailbase above the roof deck feels like the right solution to this humble pilgrim.
Foamular xps roof insulation for commercial buildings page 5 foamular xps roof insulation for commercial buildings foamular xps insulation is a rigid foam insulation which meets the needs of today s design professionals for a truly sustainable insulation product.
The roof deck can be plywood metal concrete or wood planks.
Reinforcing thin concrete with steel wire would be important to keep it from breaking up and becoming a hazard in an earthquake.
Insulation above the roof deck or air vapor impermeable insulation below the roof deck is needed for condensation control in an unvented roof.
The 6 inches of rigid insulation added to the top of the existing roof deck needed to be done in a manner that was invisible.
The bottom layer of a single ply membrane roofing system is the roof deck or substrate.
Now comes the really really big point.
Densdeck roof boards are fm tested and approved as the only 1 2 gypsum product to meet the.
Installing rigid foam insulation on top of roof sheathing is a great option for commercial buildings and homes with limited space.
The rustic bare wood ceiling look is preserved all of the structural wood stays inside the thermal pressure boundary of the building all cozy dry.
Building air tightness would now preside at the top of the building enclosure at the roof deck and attic walls gables.
The ratio of insulation above the roof deck or air permeable insulation below the roof deck is a matter of climate and interior conditions.
Owens corning insulation products help improve thermal performance and control moisture in commercial institutional and.
When installing rigid insulation in an attic to be finished as a living space you must provide a route by which hot air can escape.
Rigid foam insulation installation prepare roof deck.
This requires the use of soffit vents and a roof ridge vent to.
Gable end detail overhang cut and then rebuilt to hide the thickness of the over roofing rigid insulation.