Smoke control s visioneering range of fire rated glass systems such as fire windows glazed partition fire rated glazed doors fire resistant glass offer designers unrivaled flexibility.
Smoke resistant glass doors.
For the selection of products manufactured developed and offered by coolfire we have kept in mind the recommendations of architects operators and end users.
In the event of a fire emergency escape routes and information signs have to continue to be easily visible despite the smoke.
This section does not refer to section 710 instead it includes the requirements for openings within section 404 6.
Technical glass products is the recognized leader in fire rated glass and framing.
Explore the world of beautifully safe solutions for innovative architecture.
The european requirements regarding the smoke resistance of doors have recently been changed.
As a result the rules for smoke resistance will be more specific.
Approval for single and double leaf door elements.
Unlatched pairs and single doors giving the architect and designer freedom of choice for door furniture.
Require doors to meet the requirements for a smoke and draft control door assembly tested in accordance with ul 1784.
Wayne dalton s 9000 series steel garage doors have a center core made of polyurethane foamed in place insulation a heat resistant material that bonds the steel outer panels together.
Fire and smoke resistant architecture coolfire ltd has been present on the hungarian and international fireproof doors and windows market since january 2009.
A resin coating on the door s exterior also creates a protective barrier helping to prevent the spread of flames and reducing the amount of billowing smoke.
Section 404 6 addresses atrium enclosures and allows a glass wall forming a smoke partition with automatic sprinklers on both sides of the glass in lieu of a 1 hour fire barrier if certain criteria are met.
A wide range of options for glazed fire resistant doors with smoke resistance.
Non rebated or rebated meeting stiles.
The air leakage rate of the door assembly is not allowed to exceed 3 0 cubic feet per minute per square foot of door opening at 0 10 inch of water for both the ambient temperature test and the.
According to this standard the smoke proof capacity of the doors is tested separately.
Smoke guard provides innovative and aesthetically appealing fire and smoke protection systems to fit any purpose and any opening in your building our complete range of curtain systems is flexible both physically and in application.
From january 2021 the european standard en 1634 3 will be updated.
A choice of concealed or surface mounted face closers.
Testing to bs 476 part 22.